Vorteile

  • Neues „Flat Catheter Concept“ (FCC).
  • Höchste Stabilität und Halt (lange nasenförmige Spitze, HYBRID, große Durchmesser und Längen).
  • Größte Auswahl auf dem Markt (Längen).
  • Einfache Navigation (einlumig, HYBRID, fortschrittliche Elastizität, HYDROSPEED).
  • Schnelle Inflation und Deflation des Ballons.
  • DMSO-kompatibel.

Technische Daten


Artikelnummer

Ballon max
Ø (mm)
Ballonlänge
(mm)
Distale Spitze
O.D. x Länge
I.D.
(Hauptlumen)
Double Lumen
Äußere Dimension (Stärke)
Double Lumen
Äußere Dimension (Breite)
ECL2L 6x7SN672,0F x 3mmØ 0,41mm / .017"
(equivalent zu Vasco+10)
Ø 0,9mm
(equivalent zu 2,7F)
1,15mm
ECL2L 6x9692,0F x 3mmØ 0,41mm / .017"
(equivalent zu Vasco+10)
Ø 0,9mm
(equivalent zu 2,7F)
1,15mm
ECL2L 6x126122,0F x 7mmØ 0,41mm / .017"
(equivalent zu Vasco+10)
Ø 0,9mm
(equivalent zu 2,7F)
1,15mm
ECL2L 6x156152,0F x 7mmØ 0,41mm / .017"
(equivalent zu Vasco+10)
Ø 0,9mm
(equivalent zu 2,7F)
1,15mm
ECL2L 6x206202,0F x 7mmØ 0,41mm / .017"
(equivalent zu Vasco+10)
Ø 0,9mm
(equivalent zu 2,7F)
1,15mm

 

The ECLIPSE 2L double lumen balloon catheters are intended for use in the peripheral vasculature and neurovasculature for temporary occlusion. The balloon catheters provide temporary vascular occlusion which is useful in selectively stopping or controlling blood fl ow and for the vasospasm treatment. The balloon catheters also offer balloon assisted embolization of intracranial aneurysms. They are also indicated for use in the peripheral vasculature and neurovasculature for administration of diagnostic agents (contrast solution) and therapeutic agents (embolization materials compatible with the inner diameter of the balloon catheters ECLIPSE 2L). The content of this document, in particular data, information, trademarks and logos are BALT S.A.S and affiliates’ sole property. Consequently, all representation and/ or reproduction, whether in part or in full, is forbidden and would be considered a violation of BALT S.A.S and affi liates’ copyrights and other intellectual proprietary rights ©2017

BALT S.A.S and affi liates all rights reserved. This document with associated pictures are non-contractual and are solely dedicated to healthcare professionals and BALT S.A.S and affiliates’ distributors. The products commercialized by BALT SAS and affiliates shall exclusively be used in accordance with the package inserts which have been updated and included in the boxes. ECLIPSE 2L is class III CE marked (LNE/G-Med CE0459) according to the Medical Device Directive 93/42/EEC since 2014.